Maleic Anhydride Safety, SDS
& Handling Guide
GHS classification · OEL 0.1 ppm ceiling · Dual fire hazard · PPE · Solid & molten handling · Storage · Emergency response
🔗 View Maleic Anhydride Product Page⚠️ Safety Disclaimer: This guide provides general safety information for maleic anhydride (CAS 108-31-6) for industrial buyers and handlers. It does not replace the product's Safety Data Sheet (SDS), site-specific risk assessment, or applicable national occupational health and safety regulations. Always obtain the current SDS from your supplier and consult a qualified industrial hygienist or safety professional for site-specific risk assessment before handling MAH.
📋 Table of Contents
- GHS Classification and Hazard Summary
- Dual Fire Hazard: Solid Dust and Molten Liquid
- Health Hazards: Corrosivity, Sensitisation and OEL
- PPE Requirements: Solid Handling vs Molten Operations
- Safe Handling of Solid MAH (Flakes and Bags)
- Safe Handling of Molten MAH
- Storage Requirements
- Emergency Response: Spill, Fire and First Aid
- Transport Classification (IMDG, ADR, IATA)
- SDS and Regulatory Documents to Request
- Frequently Asked Questions
🏷️ 1. GHS Classification and Hazard Summary
🏷️ Maleic Anhydride - GHS Hazard Classification (CAS 108-31-6)
Flammable solid
Skin corrosive Cat.1
Acute tox.; irritant
STOT RE; sensitiser
| Signal word | DANGER |
| H228 | Flammable solid |
| H302 ⚠️ | Harmful if swallowed (Acute Tox. Cat. 4, oral) |
| H314 ⚠️ | Causes severe skin burns and eye damage (Skin Corr. Cat. 1) |
| H317 ⚠️ | May cause an allergic skin reaction (Skin Sens. Cat. 1) |
| H334 ⚠️ | May cause allergy or asthma symptoms or breathing difficulties if inhaled (Resp. Sens. Cat. 1) |
| H335 ⚠️ | May cause respiratory irritation (STOT SE Cat. 3) |
| H372 ⚠️ | Causes damage to organs through prolonged or repeated exposure (STOT RE Cat. 1) - respiratory system |
🚨 MAH is significantly more hazardous than most organic acid intermediates such as isooctanoic acid, isononanoic acid, or neodecanoic acid. The H314 (skin corrosive) and H334 (respiratory sensitiser) classifications are the most operationally critical hazards. H334 means that once a worker is sensitised to MAH, even trace exposures far below the OEL can trigger occupational asthma - and sensitisation is irreversible. This makes respiratory protection non-negotiable for all MAH handling operations. DANGER signal word (vs WARNING for IOA/NDA) reflects this higher hazard tier.
🔥 2. Dual Fire Hazard: Solid Dust and Molten Liquid
Maleic anhydride presents two distinct fire hazards that must be assessed and controlled separately. Many operators who are familiar only with the solid form are caught off guard by the fire hazard of molten MAH, and vice versa. Both modes are real and require specific engineering controls.
| DG classification | Class 4.1 Flammable solid |
| UN Number | UN 2215 |
| Packing Group | III |
| Dust explosion risk | MEC ~30–50 g/m³ ⚠️ |
| ATEX zone classification | Zone 22 (dust) in bag handling area |
- MAH flake dust is explosible at concentrations above ~30 g/m³ - keep bag-tipping and conveying areas free of dust accumulation
- Enclosed bag-tipping stations with local exhaust ventilation (LEV) are required
- All electrical equipment in bag-handling areas must be rated for Zone 22 dust atmospheres (ATEX Cat. 3D)
- No open flames, hot surfaces (>140°C), or spark-generating equipment in dust-generating areas
- Housekeeping: remove dust deposits promptly; MAH dust on hot surfaces (piping, steam tracing) can smoulder
| Flash point | 102°C (closed cup) ⚠️ |
| Auto-ignition temp. | 477°C |
| LEL / UEL (vapour) | 1.4% / 7.1% v/v |
| Applies above | 52.8°C (melt) ⚠️ |
| ATEX zone classification | Zone 2 (vapour) around molten MAH vessels |
- UPR synthesis reactors operating at 180–220°C are well above the flash point - N₂ inert atmosphere is mandatory
- Heated molten MAH storage tanks (60–80°C) are below flash point under normal conditions, but vent pipes must be protected with flame arrestors
- All electrical equipment in heated MAH areas must be Zone 2 rated (vapour atmosphere possible during transfer operations)
- No ignition sources near open-vent molten MAH transfer operations or heated pipe flanges
💡 ATEX/DSEAR site assessment note: A site handling both solid MAH (bag tipping) and molten MAH (heated vessels and synthesis reactors) requires two separate ATEX zone assessments - one for dust (Zone 22 or Zone 21 if significant dust release, per DSEAR/ATEX Directive 2014/34/EU) and one for vapour (Zone 2 around heated vessels). The two zones may overlap in areas where molten MAH is loaded from bags into heated tanks. Ensure all ATEX equipment documentation covers both the dust and vapour explosion group. Do not assume that Zone 2 vapour-rated equipment is automatically suitable for Zone 22 dust - the equipment group (IIA/IIB/IIC for vapour; IIIA/IIIB for dust) must be confirmed for the specific hazard.
🏥 3. Health Hazards: Corrosivity, Sensitisation and OEL
MAH is classified as a Skin Corrosive Category 1 (H314: causes severe skin burns and eye damage). This is one hazard tier more severe than an irritant:
- Solid MAH dust or flakes on moist skin → maleic acid forms on contact with sweat; continued contact causes chemical burn; rinse immediately with large amounts of water for at least 20 minutes
- Molten MAH on skin → simultaneous thermal burn + chemical corrosion; more severe injury than either alone; flush with water for at least 30 minutes; seek medical attention immediately
- Eye contact: Any MAH contact with eyes is a medical emergency - immediate flushing with water for minimum 20 minutes and immediate medical evaluation; risk of permanent vision damage
- Do not neutralise burns with alkali - just flush with copious water; neutralisation reactions are exothermic and can worsen injury
H334 is the most operationally important hazard classification for MAH:
- What it means: Repeated inhalation of MAH dust or vapour - even at sub-OEL concentrations - can cause occupational asthma (sensitisation). Once a worker is sensitised, subsequent exposures to even trace concentrations can trigger severe asthma attacks
- Irreversibility: Sensitisation is permanent - a sensitised worker can never again work with MAH without risk of asthma attack; job transfer is typically required
- Surveillance requirement: Workers regularly exposed to MAH should undergo baseline and annual respiratory health surveillance (spirometry + symptom questionnaire per national OH&S requirements)
- First exposure: Even first-time exposures at moderate concentrations can cause acute bronchospasm in susceptible individuals; do not assume "this person has never had a reaction before" guarantees no risk
| ACGIH TLV-C ⭐ | 0.1 ppm (ceiling) |
| EU IOELV (indicative) | 0.1 ppm / 0.41 mg/m³ |
| UK WEL (8-hr TWA) | 0.1 ppm |
| Germany MAK | 0.1 ppm (ceiling) |
| NIOSH REL (TWA) | 0.1 ppm |
| OEL type | Ceiling - never exceeds ⚠️ |
The TLV-C designation means the 0.1 ppm limit must NEVER be exceeded at any instantaneous measurement - it is not an 8-hour average. This is one of the most stringent OELs for any common industrial chemical and reflects the respiratory sensitisation risk.
🦺 4. PPE Requirements: Solid Handling vs Molten Operations
| PPE Item | Solid MAH Handling (bags, flakes) | Molten MAH (heated vessels, transfers) |
|---|---|---|
| Respiratory protection ⭐ | FFP3 (P3) dust respirator or powered PAPR with P3 filter - mandatory when opening bags or where dust may be generated ⚠️ | OV/P3 combination respirator or airline breathing apparatus for open molten vessel work ⚠️ |
| Eye/face protection ⭐ | Full-face shield (ANSI Z87.1 or EN 166) AND chemical splash goggles - both required | Full-face shield rated for chemical splash AND thermal splash - face shield must cover full face and neck ⚠️ |
| Hand protection | Chemical-resistant gloves: nitrile (≥0.15 mm) or butyl rubber; minimum elbow-length for bag tipping | Thermal-insulating + chemical-resistant gloves: butyl rubber over cotton liner; shoulder-length recommended ⚠️ |
| Body protection | Chemical-resistant coverall (Type 5/6); no skin exposure; safety boots with chemical resistance | Heat-resistant chemical splash suit (PVC or rubber-coated); no synthetic fibres that could melt onto skin ⚠️ |
| Emergency shower/eyewash | Within 10 seconds walking distance; ANSI Z358.1 compliant; operable without hands | Within 10 seconds - ideally immediately adjacent to any molten MAH operation ⚠️ |
⚠️ Standard dust masks (FFP1/FFP2) are NOT adequate for MAH. The OEL-C of 0.1 ppm requires FFP3/P3 rated respiratory protection for any operation where dust may be present in the breathing zone. Simple nuisance dust masks (disposable, non-rated) provide no protection against MAH at these concentrations. For engineering control preference: enclosed bag-emptying stations with LEV eliminate the need for respiratory PPE during routine operations and are always preferable to relying on personal RPE.
📦 5. Safe Handling of Solid MAH (Flakes and Bags)
- Inspect bags on delivery - any torn, wet, or heavily deformed bags should be segregated and handled with extra caution (moisture-damaged MAH may have converted partially to maleic acid)
- Verify batch number on bag matches COA; confirm CAS 108-31-6 on label
- Check crystallisation point on COA - bags showing evidence of moisture damage (caking, hard lumps, discolouration) should be tested before use
- Store in original sealed bags until ready for use - do not open bags in advance of production
- Use enclosed bag-tipping station with integral LEV - minimum face velocity 0.5 m/s at bag opening
- Do not cut bags with knives or blades that generate sparks - use ceramic or plastic cutters in dust-generating areas
- Full PPE (FFP3 respirator, face shield, chemical gloves, coverall) before opening bags
- Do not tip bags into hot vessels (>80°C) - risk of rapid MAH vapour generation and sudden flash; melt MAH separately at 60–70°C in a pre-melt vessel, then transfer as liquid
- Clean up any spilled flakes immediately using damp mop or vacuum with HEPA filter - do not dry-sweep (generates airborne dust)
- Water/moisture - hydrolysis to maleic acid; exothermic; product quality loss; never store in humid conditions or open bags during rain
- Strong bases (NaOH, KOH, NH₃) - violent exothermic ring-opening; neutralisation with undiluted alkali can cause spattering and thermal injury
- Strong oxidisers (H₂O₂, KMnO₄, ClO₂) - risk of fire or explosion
- Amines (primary/secondary) - near-instantaneous ring-opening; exothermic; only mix intentionally in a controlled reactor setting
- Aluminium, copper, and brass equipment - maleic acid (from moisture-damaged MAH) corrodes these metals; use SS 316L or plastic-lined equipment throughout
🌡️ 6. Safe Handling of Molten MAH
Molten MAH (above 52.8°C) introduces hazards not present with solid MAH: thermal burn risk in addition to chemical corrosion, vapour pressure generating inhalation hazard, and flammable liquid fire risk above 102°C flash point. All molten MAH operations must be treated as significantly more hazardous than solid handling.
- Operating temperature: maintain at 60–75°C; avoid temperatures above 90°C unnecessarily to reduce vapour pressure and risk of maleic acid formation from moisture contamination
- Nitrogen blanket: apply N₂ to tank headspace; prevents moisture ingress (which causes hydrolysis) and keeps vapour concentration below LEL
- Pressure relief: tanks must have pressure relief valve (PRV) set to low pressure to prevent build-up from N₂ blanket or vapour; PRV discharge must be vented to safe location away from personnel and ignition sources
- Level measurement: use radar or ultrasonic level instruments rated for MAH service (corrosion-resistant); avoid glass-sight glasses (risk of breakage and MAH splash exposure)
- Water exclusion: absolutely no water ingress into hot molten MAH tanks - violent boiling and MAH spattering can occur
- Heat tracing: all MAH pipework must be heat-traced (steam or electric) to prevent solidification and blockage; trace should maintain ≥60°C throughout
- Inert atmosphere: N₂ blanket throughout synthesis - from initial MAH melt through polycondensation to product cooling; no air purge of reactor at synthesis temperature
- Reactor venting: condenser on reactor overhead must be operational to capture MAH vapour and water of condensation; MAH vapour must not be discharged directly to atmosphere
- Temperature monitoring: thermocouples in reactor and jacket; interlock to shut off heating if reactor temperature exceeds 240°C (risk of premature crosslinking and pressure build-up)
- Addition rate: add solid MAH to the glycol charge gradually - rapid addition of large quantities to a hot reactor can cause sudden exotherm; follow recipe addition protocol
- Styrene addition: cool polyester melt to ≤120°C before adding styrene; adding styrene to a hot melt (>150°C) can cause violent styrene vapour evolution and ignition
🏪 7. Storage Requirements
| Storage Parameter | Solid MAH (bags/big bags) | Molten MAH (heated tank) |
|---|---|---|
| Temperature | <40°C (avoid partial melting and caking); <30°C preferred for long-term storage | 60–75°C; maintain above melting point; nitrogen blanket |
| Humidity / moisture | Keep bags sealed; store in dry building (<60% RH); pallet-wrap and cover with waterproof sheeting; never store outdoors | N₂ blanket on tank headspace; desiccant breather on N₂ inlet; absolutely exclude water |
| Shelf life | 12 months in sealed original packaging in dry conditions; test crystallisation point if near or past 12 months before use | Process within 30 days of filling heated tank; long-term hot storage causes gradual colour development |
| Segregation | Separate from oxidisers, strong bases, amines, food products; not adjacent to steam pipes or heat sources >45°C | Bunded area; no water lines overhead; no process water or steam connections without non-return valves |
| Ventilation | General natural ventilation adequate if bags remain sealed; LEV required at bag-opening point | Forced mechanical ventilation; continuous MAH vapour monitoring recommended (>0.05 ppm alarm level) |
| Container materials | Original PE-lined kraft bags; do not transfer to aluminium, copper, or galvanised containers | Stainless steel 316L; glass-lined; PTFE-lined; no aluminium, copper, galvanised steel, or rubber (non-MAH-resistant) |
🚨 8. Emergency Response: Spill, Fire and First Aid
- Evacuate non-essential personnel; ventilate area
- Full PPE before entering spill area (FFP3 + face shield + chemical suit + gloves)
- Solid spill: Collect with damp mop or HEPA vacuum; do not dry-sweep; place in sealed plastic container labelled as MAH waste
- Molten spill: Allow to solidify before attempting clean-up; bund spill if possible using sand/inert material; never add water to large molten spill
- Contaminated material: dispose as hazardous waste (corrosive solid) per local regulations
- Notify environment team if MAH enters drain - maleic acid can harm aquatic organisms (EC50 <10 mg/L for some species)
- Extinguishing agents: CO₂, dry powder, foam - these are the preferred agents
- DO NOT use water jets on molten MAH fires - water contact with hot MAH causes violent spattering and steam generation; if water must be used, use only fine water spray/mist from safe distance for cooling surrounding equipment
- Small solid MAH fires: CO₂ or dry powder; ventilate area; evacuate non-firefighting personnel
- Full fire-fighting PPE required (SCBA, chemical-resistant suit) - MAH combustion produces CO, CO₂, and maleic acid vapour (toxic/irritant decomposition products)
- Prevent fire-fighting runoff from entering drains or waterways - collect in bund if possible
- Skin contact: Remove contaminated clothing immediately; flush skin with large amounts of water for minimum 20 minutes; seek medical attention; do not attempt neutralisation
- Eye contact: Immediately flush eyes with water for minimum 20 minutes, keeping eyelids open; seek emergency medical attention immediately; do not delay
- Inhalation: Remove to fresh air; if breathing is difficult or bronchospasm develops, administer bronchodilator (if available) and call emergency services; persons with history of MAH sensitisation may need immediate medical treatment
- Ingestion: Rinse mouth with water; do NOT induce vomiting; give water to drink; seek immediate medical attention
- All significant exposures: Report to occupational health; document for respiratory sensitisation surveillance record
🚢 9. Transport Classification (IMDG, ADR, IATA)
| Mode | Regulation | UN No. | Proper Shipping Name | Class | PG | Special Provisions |
|---|---|---|---|---|---|---|
| Sea (IMDG) | IMDG Code | 2215 | MALEIC ANHYDRIDE, MOLTEN or MALEIC ANHYDRIDE (solid) | 4.1 | III | EmS F-A, S-G; stow "away from foodstuffs"; Category A stowage |
| Road (ADR) | ADR 2023 | 2215 | MALÉIC ANHYDRIDE FONDU / MALEIC ANHYDRIDE | 4.1 | III | Tunnel restriction: D/E; tanker code: L4BN (molten) |
| Air (IATA) | IATA DGR | 2215 | Maleic anhydride, solid | 4.1 | III | Permitted on cargo and passenger aircraft; packaging instruction 445/Y445 |
| Rail (RID) | RID | 2215 | ANHYDRIDE MALÉIQUE FONDU | 4.1 | III | Same classification as ADR; heated tank wagons for molten |
💡 Molten MAH transport note: When MAH is transported as a molten liquid (in heated ISO tanks or road tankers), it must be declared separately as "MALEIC ANHYDRIDE, MOLTEN" - the molten form has additional special provisions compared to the solid. Heated ISO tanks for molten MAH must be maintained at 60–75°C throughout transport; the transport document must state the substance is transported in a molten state; emergency sheets (Tremcard) must be available in the transport vehicle. Sinolook Chemical provides all required DG documentation for both solid and molten MAH shipments as standard.
📄 10. SDS and Regulatory Documents to Request
| GHS SDS ⭐ | 16-section REACH Annex II format; in your language; confirms H228, H302, H314, H317, H334, H335, H372; Section 14 with UN 2215, Class 4.1 |
| Batch COA ⭐ | Purity, APHA, maleic acid content, crystallisation point, Fe; batch number matching drum/bag label |
| DGD | Dangerous Goods Declaration: UN 2215, Class 4.1, PG III; signed by certified DG adviser |
| REACH OR letter | EU buyers: confirms REACH registration status; references CAS 108-31-6 |
| TSCA cert. | US buyers: TSCA positive certification confirming CAS 108-31-6 active inventory status |
| Transport emergency card | Tremcard or equivalent for road transport; required in some jurisdictions for ADR compliance |
| OEL stated | ≤0.1 ppm (TLV-C ceiling) |
| Respiratory protection | FFP3 / P3 or better specified |
| Skin protection | Chemical-resistant gloves + coverall |
| Eye protection | Full-face shield specified |
| Engineering controls | LEV and N₂ atmosphere noted |
| DNEL (inhalation) | Worker DNEL confirmed present |
If a supplier's SDS does not show H334 (respiratory sensitiser) or does not specify FFP3 respiratory protection for MAH, it may be incomplete or out-of-date - request an updated SDS.
❓ 11. Frequently Asked Questions
Q1: What is the GHS hazard classification of maleic anhydride?
Maleic anhydride (CAS 108-31-6) is classified under GHS with the signal word DANGER and the following hazard statements: H228 (Flammable solid); H302 (Harmful if swallowed, Acute Tox. Cat.4 oral); H314 (Causes severe skin burns and eye damage, Skin Corr. Cat.1); H317 (May cause an allergic skin reaction, Skin Sens. Cat.1); H334 (May cause allergy or asthma symptoms or breathing difficulties if inhaled, Resp. Sens. Cat.1); H335 (May cause respiratory irritation, STOT SE Cat.3); H372 (Causes damage to organs through prolonged or repeated exposure, STOT RE Cat.1 - respiratory organs). The four GHS pictograms are GHS02 (flame), GHS05 (corrosion), GHS07 (exclamation), and GHS08 (health hazard). The H314 and H334 classifications are the most operationally significant: H314 means MAH is a skin and eye corrosive requiring the same protection level as concentrated acid or alkali; H334 means MAH is a respiratory sensitiser where a ceiling OEL of 0.1 ppm must never be exceeded and where workers should undergo health surveillance. This classification is considerably more hazardous than the branched fatty acids (IOA, INA, NDA) which carry at most H315/H319 (irritant) - MAH's corrosive and sensitiser classifications are due to its reactive anhydride ring structure, which is absent in the fatty acid homologues.
Q2: What is the OEL (occupational exposure limit) for maleic anhydride?
The occupational exposure limit (OEL) for maleic anhydride is 0.1 ppm, universally set as a ceiling value (TLV-C) - meaning this concentration must never be exceeded at any instantaneous measurement, not just as an 8-hour time-weighted average. This ceiling designation is applied specifically because MAH is a respiratory sensitiser (H334): there is no safe "average" exposure level for a sensitiser, because intermittent peak exposures above the ceiling are the primary trigger for occupational asthma development, regardless of what the 8-hour average might be. The 0.1 ppm TLV-C is equivalent to 0.41 mg/m³. This is one of the most stringent OELs for any common industrial chemical intermediate - for comparison, the OEL for phthalic anhydride is 1 ppm (10× higher) and for acetic acid is 10 ppm (100× higher). The extreme stringency reflects the fact that sensitisation from MAH exposure is irreversible - a sensitised worker can never safely return to work with MAH. Practical control measures to achieve the 0.1 ppm ceiling: enclosed MAH handling systems with LEV; N₂ atmosphere over heated MAH; continuous air monitoring with alarm set at 0.05 ppm; FFP3 respirator as backup for non-routine operations; minimise open-vessel operations with molten MAH above 70°C.
Q3: What type of gloves should I use when handling maleic anhydride?
For solid MAH handling (bag tipping, flake handling), minimum glove specification is nitrile rubber ≥0.15 mm thickness (elbow-length recommended to protect forearms during bag tipping) or butyl rubber. Latex gloves are not recommended because MAH can sensitise via skin contact and latex allergy is additive. For molten MAH operations (heated transfers, reactor sampling), nitrile is insufficient because it does not provide adequate thermal protection - use butyl rubber or PVC chemical-resistant gloves over cotton thermal inner gloves, shoulder-length, to protect both from chemical exposure and thermal burns. The glove material must be tested for resistance to MAH (maleic acid equivalent): EN 374 breakthrough time should be >480 minutes for the chosen material and thickness. Key points: (1) inspect gloves for punctures before each use - MAH skin corrosion through a pinhole defect in a glove is a serious injury risk; (2) remove gloves carefully after use to avoid contaminating hands with the external surface; (3) gloves that have been in contact with MAH should be rinsed with water before removal, then washed or disposed of as hazardous waste; (4) do not touch face or adjust respiratory protection while wearing MAH-contaminated gloves.
Q4: What fire extinguisher should be used for maleic anhydride fires?
For maleic anhydride fires, the correct extinguishing agents are CO₂, dry powder (ABC), or foam. The critical rule is: do not use water jets on molten MAH fires. When a water jet contacts hot molten MAH, it causes violent steam generation and MAH spattering - this can spread burning material and cause severe burns to firefighters. Fine water mist or spray can be used carefully to cool surrounding equipment and structures, but only from a safe distance. For solid MAH fires (bags or spilled flakes), CO₂ or dry powder is preferred; these fires tend to be surface-burning and controllable with appropriate extinguishers. For larger fires involving heated MAH storage tanks or process equipment, the emergency response should be: (1) evacuate non-essential personnel; (2) alert emergency services; (3) use fixed suppression systems (foam or dry powder deluge) if installed; (4) cool adjacent equipment with water spray but keep water away from burning MAH; (5) SCBA is mandatory for any firefighters in the area due to toxic combustion products (CO, CO₂, acrolein, maleic acid vapour). Combustion of MAH produces carbon monoxide and irritant decomposition products including maleic anhydride vapour and maleic acid mist - all are serious inhalation hazards.
Q5: Does Sinolook Chemical provide an SDS for maleic anhydride?
Yes - Sinolook Chemical provides a current GHS-compliant Safety Data Sheet (SDS) for maleic anhydride (CAS 108-31-6) in 16-section REACH Annex II format (Commission Regulation 2020/878). The SDS is available in English and can be provided in German, French, Spanish, Italian, and Chinese upon request. The SDS includes all required information: Section 2 with full GHS classification (H228, H302, H314, H317, H334, H335, H372) and DANGER signal word; Section 8 with OEL 0.1 ppm (ceiling) and PPE specifications including FFP3 respiratory protection; Section 9 with physical properties including melting point 52.8°C, flash point 102°C, and vapour pressure data; Section 14 with transport classification UN 2215, Class 4.1, PG III. The SDS is provided as standard documentation with every MAH shipment, along with the batch COA, REACH OR letter (EU customers), TSCA positive certification (US customers), and Dangerous Goods Declaration (DGD). To receive the SDS in advance of an order, or to confirm the current revision date, contact us at sales@sinolookchem.com or WhatsApp 0086 18150362095. You can also view our maleic anhydride product page at sinolookchem.com/personal-care-chemicals/maleic-anhydride.html.
Request SDS, COA & Full Safety Documentation for Maleic Anhydride
Contact Sinolook Chemical
MAH CAS 108-31-6 · SDS in multiple languages · REACH OR · TSCA cert ✅
Full DG Class 4.1 documentation · UN 2215 · 25 kg bags & big bags · 50+ countries