2-Methyl-1,3-Propanediol Physical and Chemical Properties: Full Technical Data Reference

Apr 07, 2026

Leave a message

MPD · CAS 2163-42-0 · Physical & Chemical Properties · Technical Data

2-Methyl-1,3-Propanediol Physical & Chemical Properties:
Full Technical Data Reference

Thermodynamic constants · Transport properties · Solubility · Thermal stability · Spectroscopic identifiers · Handling parameters

🔗 View MPD Product Page

📊 Data note: Values compiled from PubChem CID 12671, NIST WebBook, manufacturer TDS (LyondellBasell MPD technical data), and peer-reviewed literature. Where ranges appear, they reflect variation across sources or temperature dependence. Always verify critical parameters against the COA for each specific batch.

🏷️ 1. Molecular Identity & Registration Numbers

Identifier Value
Preferred IUPAC Name 2-Methylpropane-1,3-diol
Trade abbreviations MPD; MPO; 2-Me-1,3-PDO
CAS Registry Number 2163-42-0
EC / EINECS Number 218-551-0
PubChem CID 12671
Molecular Formula C₄H₁₀O₂
Molecular Weight 90.12 g/mol
InChI InChI=1S/C4H10O2/c1-4(2-5,3-6)7/h5-6H,2-3H2,1H3
InChIKey SBASXUCJHJRPEV-UHFFFAOYSA-N
SMILES OCC(C)CO
INCI Name (cosmetics) 2-Methyl-1,3-Propanediol
HS Code (trade) 2905.39 (other diols)

🌡️ 2. Thermal & Phase Properties

MPD's thermal profile is dominated by its wide liquid range (−91 °C to 212 °C at atmospheric pressure) and relatively high boiling point for its molecular weight, both of which reflect the strong hydrogen-bond network formed by its two hydroxyl groups.

Property Value Notes / Conditions
Boiling point 211–213 °C At 760 mmHg (101.3 kPa); lit. 212 °C (NIST)
Boiling point (reduced pressure) 100 °C at ~6 mmHg; 130 °C at ~20 mmHg Useful for vacuum distillation / stripping operations
Melting point −91 °C Liquid at all practical storage & processing temperatures; no heating required
Flash point 107 °C (closed cup) Combustible liquid (not flammable at RT); no Class 3 DG classification for sea freight
Auto-ignition temperature ~340 °C Well above normal processing temperatures; standard fire precautions apply
Explosive limits (LEL / UEL) ~1.6% / ~10.4% (v/v in air) At elevated temperatures near or above flash point; relevant to heated process vessels
Vapour pressure (25 °C) < 0.1 mmHg (< 13 Pa) Very low VP; negligible vapour at room temperature; minimal inhalation risk during cold handling
Vapour pressure (60 °C) ~1–2 mmHg Still very low; heated process vessels should be ventilated
Critical temperature ~425 °C (estimated) Estimated from group contribution methods; above thermal decomposition onset
Thermal decomposition onset > 250 °C Stable under normal processing conditions up to ~250 °C; decomposes at higher temperatures
Enthalpy of vaporisation (at BP) ~62 kJ/mol (estimated) Higher than simple alcohols; reflects strong H-bond network; relevant for distillation energy calculations

⚙️ 3. Transport Properties: Density, Viscosity & Surface Tension

Transport properties govern how MPD behaves in pumping, mixing, and coating operations. MPD's relatively low viscosity for a diol of its molecular weight and functionality is one of its practical process advantages.

Property Value Notes
Density (20 °C) 1.006–1.010 g/cm³ Slightly denser than water; sinks in aqueous two-phase systems
Density (25 °C) 1.002–1.005 g/cm³ Standard reference temperature for formulation work
Density temperature coefficient (dρ/dT) −0.00080 g/(cm³·°C) Use to correct density at other temperatures; relevant for tank gauging
Dynamic viscosity (20 °C) ~95–110 mPa·s Moderate; comparable to light mineral oil
Dynamic viscosity (25 °C) ~75–90 mPa·s Standard pump design reference temperature
Dynamic viscosity (50 °C) ~25–35 mPa·s Significant reduction; heating to 40–50 °C recommended for high-volume pump transfer
Kinematic viscosity (25 °C) ~75–90 mm²/s (cSt) ν = η/ρ; relevant for gravity-flow and pipe sizing calculations
Surface tension (25 °C) ~34–36 mN/m Lower than water (72 mN/m); assists wetting in coating applications
Specific heat capacity (liquid, 25 °C) ~2.3 J/(g·°C) Used for heat exchanger and reactor design calculations
Thermal conductivity (liquid, 25 °C) ~0.22 W/(m·K) (estimated) Estimated; lower than water; relevant for reactor heat transfer design

💡 Viscosity context: MPD's viscosity (~80 mPa·s at 25 °C) is approximately 80× that of water, but substantially lower than glycerol (~1,400 mPa·s) and comparable to a light gear oil. This makes MPD pumpable at ambient temperature with standard centrifugal or gear pumps without heating - a practical advantage over heavier polyols and solid diols such as NPG or 1,4-BDO (which must be melted before processing).

💧 4. Solubility & Miscibility

MPD's solubility profile reflects its dual nature: the two hydroxyl groups provide strong hydrogen-bonding capacity (enabling full water miscibility), while the methyl branch and four-carbon backbone provide moderate affinity for nonpolar solvents. This combination makes MPD a broadly compatible formulation ingredient.

Solvent / Medium Miscibility with MPD Notes
Water ✅ Fully miscible All proportions; key for waterborne coating formulations and personal care
Ethanol / Methanol ✅ Fully miscible Good cosolvent with alcohols; typical in personal care and specialty formulations
Acetone / MEK ✅ Miscible Common co-solvents in polyester and PU processing
Ethyl acetate / Butyl acetate ✅ Miscible Useful for coating solvent blends containing MPD as reactive component
Toluene / Xylene ⚠️ Partially miscible Limited solubility; phase separation possible at higher aromatic content; use blended solvent systems
Hexane / Mineral spirits ❌ Essentially immiscible Very limited miscibility with aliphatic hydrocarbons; MPD is too polar for nonpolar solvent systems
Glycerol / Propylene glycol ✅ Miscible Compatible with other polyol humectants; useful for personal care multi-polyol blends
Polyester polyols / Polyether polyols ✅ Compatible Mixes readily with industrial polyol systems used in PU formulation

📐 Hansen Solubility Parameters for MPD (estimated)

~16.0
δd - Dispersion (MPa½)
Van der Waals forces
~7.0
δp - Polar (MPa½)
Dipole–dipole
~21.0
δh - H-bond (MPa½)
Hydrogen bonding
~27.4
δt - Total (MPa½)
√(δd²+δp²+δh²)

The high δh value reflects the two strong OH hydrogen-bond donors/acceptors. This places MPD closer to ethanol (δt ~26.5) than to glycerol (δt ~36) in solubility space - more hydrophilic than simple esters, less so than polyols with three OH groups.

⚗️ 5. Reactivity & Chemical Properties

MPD's reactivity is dominated by its two primary aliphatic hydroxyl groups. These groups are chemically equivalent (both primary) and react predictably with a wide range of electrophilic species - acids, anhydrides, isocyanates, epoxides - making MPD a reliable bifunctional building block for polymer and specialty chemical synthesis.

Reaction Type Reagent / System Product & Application
Esterification Adipic acid, phthalic anhydride, isophthalic acid, maleic anhydride Polyester polyols for coatings, PU, alkyd resins; plasticiser dibenzoates
Urethane formation MDI, TDI, HDI, IPDI (isocyanates) Polyurethane chain extension; PU prepolymer modification; PU elastomers
Etherification Alkyl halides (under base); dehydration (acid catalyst, high T) Polyether polyols; specialty ethers as solvents or intermediates
Carbonate formation CO₂ (supercritical), dialkyl carbonates, phosgene Cyclic carbonate (4-membered ring); polycarbonate polyols for PU
Oxidation Chromic acid, TEMPO/NaOCl, periodate Aldehyde or acid products; not industrially relevant for MPD itself
Acetal formation Aldehydes (formaldehyde, benzaldehyde) + acid catalyst Cyclic acetals; useful as protecting groups in fine chemical synthesis
Hydroxyl Value
~1,220 mg KOH/g
High - 2 OH per 90.12 g/mol; ~13.6 meq OH/g
Equivalent Weight
45.06 g/eq
MW 90.12 ÷ 2 OH groups
Functionality (f)
f = 2
Difunctional diol; linear polymer chains (no cross-linking)
pKa (OH groups)
~14–15
Aliphatic alcohol; weak acid; strong base required for deprotonation
Incompatibilities
Strong oxidisers, acids, bases
Reacts vigorously with strong oxidising agents; avoid concentrated H₂SO₄/HNO₃

🔭 6. Spectroscopic & Optical Properties

Spectroscopic and optical data are used for identity confirmation (incoming QC), purity assessment, and research characterisation. The most practically important parameters for industrial QC are refractive index (fast, non-destructive) and GC purity.

Parameter Value Application
Refractive index nD (20 °C) 1.445–1.447 Primary QC identity test; fast Abbe refractometer measurement; spec range on COA
Refractive index nD (25 °C) ~1.443–1.445 −0.0004/°C temperature coefficient; correct if measuring at non-standard temperatures
Colour (APHA) Industrial: ≤ 20 · Cosmetic: ≤ 10 ASTM D1209; virtually water-white for premium grades
UV absorption Transparent below 210 nm No significant UV chromophore; UV-transparent solvent in analytical applications
¹H NMR (characteristic shifts, CDCl₃) δ 3.45–3.55 (CH₂OH, 4H); δ 1.78 (CH, 1H); δ 0.88 (CH₃, 3H) Identity and purity confirmation in research; OH protons ~2–4 ppm (broad, variable)
¹³C NMR (CDCl₃) δ ~67 (CH₂OH); δ ~35 (CH); δ ~13 (CH₃) Three distinct carbon environments; used for structural confirmation
IR (key absorptions) 3,200–3,400 cm⁻¹ (broad O–H stretch); 1,050 cm⁻¹ (C–O stretch) Characteristic diol spectrum; broad OH stretch diagnostic; C–O at 1,050 confirms aliphatic alcohol
GC retention (ref.) Elutes after 1,2-propanediol, before 1,3-butanediol on polar columns (e.g. DB-FFAP) GC-FID purity method; confirm column and oven programme with supplier

🦺 7. Safety-Relevant Physical Data

The safety-relevant physical parameters below underpin the hazard classification, storage requirements, and PPE selection for MPD. MPD is classified as a combustible liquid (not flammable at ambient temperature) and a mild irritant under GHS.

📋 GHS Classification (UN GHS Rev. 8)
  • Combustible liquid (flash point 107 °C)
  • Skin irritation: Category 3 (mild irritant)
  • Eye irritation: Category 2B (mild)
  • NOT classified as: carcinogen, mutagen, reproductive toxin, CMR
  • Signal Word: WARNING
  • Hazard statements: H227 (combustible liquid); H316 (mild skin irritant); H320 (mild eye irritant)
🌬️ Occupational Exposure
  • No OSHA PEL established for MPD
  • No ACGIH TLV established for MPD
  • Very low vapour pressure (<0.1 mmHg at 25 °C) means negligible inhalation risk at room temperature
  • Heated operations (>60 °C): ensure local exhaust ventilation
  • Repeated skin contact: use gloves (nitrile or neoprene); PPE: safety glasses, chemical apron
💊 Toxicological Summary
  • Oral LD₅₀ (rat): > 2,000 mg/kg (low acute toxicity)
  • Dermal LD₅₀ (rabbit): > 2,000 mg/kg
  • Inhalation LC₅₀: not determined (negligible vapour pressure)
  • No evidence of carcinogenicity in available studies
  • Readily biodegradable (BOD₅/COD ratio > 0.5 for related diols)
  • Approved as cosmetic ingredient (CIR reviewed; EU CosIng listed)

📊 8. Property Comparison: MPD vs Structurally Related Diols

The table below enables direct data comparison between MPD and the diols most often considered as alternatives or complements in formulation work. For a full application-focused analysis, see MPD vs Neopentyl Glycol vs 1,3-Propanediol: Which Diol for Your Formulation?

Property MPD ⭐ NPG 1,3-PDO 1,4-BDO 2-Ethyl-1,3-hexanediol
CAS 2163-42-0 126-30-7 504-63-2 110-63-4 94-96-2
MW (g/mol) 90.12 104.15 76.09 90.12 146.23
State at 25 °C Liquid Solid Liquid Solid* Liquid
Melting point (°C) −91 124 −27 20 −40
Boiling point (°C) 212 210 214 230 244
Flash point (°C) 107 129 129 121 127
Density (g/cm³, 25°C) 1.003 1.063 (melt) 1.053 1.017 0.932
Viscosity (mPa·s, 25°C) ~82 Solid ~56 Solid ~31
Water miscibility ✅ Full ✅ Full (melt) ✅ Full ✅ Full Slight
OH value (mg KOH/g) ~1,220 ~1,080 ~1,475 ~1,244 ~768
DG sea freight? No ✅ No ✅ No ✅ No ✅ No ✅

*1,4-BDO melting point 20 °C - may be solid in cold climates or cold storage; typically supplied as a melt or heated IBC.

 

❓ 9. Frequently Asked Questions

Q1: What is the boiling point of 2-methyl-1,3-propanediol?

The boiling point of MPD is 211–213 °C at atmospheric pressure (760 mmHg). This relatively high boiling point for a C4 diol reflects the strong hydrogen-bond network formed by two hydroxyl groups. For vacuum distillation or solvent stripping operations, MPD boils at approximately 100 °C at 6 mmHg and 130 °C at 20 mmHg - useful operating points for removing MPD from reaction mixtures under reduced pressure without thermal decomposition.

Q2: What is the molecular weight of 2-methyl-1,3-propanediol?

The molecular weight of MPD is 90.12 g/mol, corresponding to the molecular formula C₄H₁₀O₂. This is identical to the molecular weight of 1,4-butanediol (also C₄H₁₀O₂, 90.12 g/mol) - the two compounds are structural isomers. The equivalent weight for hydroxyl reactivity calculations is 45.06 g/eq (MW divided by the number of OH groups, 2). The hydroxyl value is approximately 1,220 mg KOH/g.

Q3: Is MPD viscous at room temperature?

MPD has a dynamic viscosity of approximately 75–90 mPa·s at 25 °C - about 80 times the viscosity of water but far lower than glycerol (~1,400 mPa·s) and much lower than many polymer intermediates. It is pumpable at room temperature with standard centrifugal or gear pumps without heating. This is a practical advantage over solid diols (NPG melts at 124 °C; 1,4-BDO melts at 20 °C) and over highly viscous alternatives like glycerol. For tank transfers and drum emptying in cold climates (below 15 °C), mild warming to 30–40 °C will reduce viscosity to ~40–50 mPa·s for easier handling.

Q4: What is the MSDS / SDS for 2-methyl-1,3-propanediol?

A full GHS-compliant Safety Data Sheet (SDS) for MPD covers: Section 1 (identification: CAS 2163-42-0, MPD/MPO), Section 2 (hazards: combustible liquid H227, mild skin/eye irritant H316/H320), Section 7 (handling: store away from heat sources and strong oxidisers; no special ventilation required at room temperature), Section 8 (PPE: nitrile gloves, safety glasses; no respiratory protection required at room temperature due to very low vapour pressure). Sinolook Chemical provides a current GHS-compliant SDS with every shipment. For our full safety and handling guide, see MPD Safety & SDS Guide.

Q5: How is the refractive index used to verify MPD quality on arrival?

Refractive index (RI) measurement is the fastest and most convenient identity QC test for MPD. Using a standard Abbe refractometer, measure the RI of the incoming material at 20 °C. Specification: nD²⁰ = 1.445–1.447 for cosmetic grade; 1.443–1.449 for industrial grade. A measurement outside this range indicates possible contamination, wrong product, or significant impurity content. If the RI is correct, follow up with GC purity analysis for complete confirmation. Note that the temperature coefficient is approximately −0.0004/°C - if measuring at 25 °C instead of 20 °C, expect a reading approximately 0.002 lower than the 20 °C specification.

Q6: At what temperature does MPD begin to decompose?

MPD is thermally stable under normal processing conditions up to approximately 250 °C. Above this temperature, dehydration and other decomposition reactions begin to occur, producing unsaturated intermediates and aldehydes. In polyester synthesis (where temperatures typically reach 200–230 °C with catalyst), MPD is stable throughout the condensation process. The auto-ignition temperature is approximately 340 °C. For prolonged exposure above 230 °C (e.g. extended hold times in a reactor), nitrogen blanketing is recommended to prevent oxidative degradation and colour development in the product.

Source High-Purity MPD with Full Technical Documentation

Contact Sinolook Chemical

Industrial grade & cosmetic grade MPD · Batch COA with RI, GC purity, OH value, colour & water content
REACH OR support for EU buyers · Export to 50+ countries · Drums, IBC & ISO tanks

📱 WhatsApp: 0086 18150362095
💬 WeChat / Tel: 0086 13400715622
✉️ Email: sales@sinolookchem.com
🔗 View MPD Product Page
Send Inquiry